Catalog :




Detail Article

Indonesian Journal of Clinical Pathology and Medical Laboratory

ISSN 0854-4263

Vol. 12 / No. 3 / Published : 2006-07

Related with : Scholar   Yahoo!   Bing

Original Article :

The haematology reference value of healthy adult people based on sysmex xt-1800i

Author :

  1. T.Esa*1
  2. S.Aprianti*2
  3. M.Arif*3
  4. Hardjoeno*4
  1. Bagian Patologi Klinik FK.UNHAS/RS. Dr. Wahidin Sudirohusodo Makassar/ Unit Pelayanan Laboratorium RS Dr. Wahidin Sudirohusodo Jl. Perintis Kemerdekaan Km 10. Makassar Telp : 0411–582678/586010
  2. Bagian Patologi Klinik FK.UNHAS/RS. Dr. Wahidin Sudirohusodo Makassar/Unit Pelayanan Laboratorium RS Dr. Wahidin Sudirohusodo Jl. Perintis
    Kemerdekaan Km 10. Makassar Telp : 0411–582678/586010
  3. Bagian Patologi Klinik FK.UNHAS/RS. Dr. Wahidin Sudirohusodo Makassar/Unit Pelayanan Laboratorium RS Dr. Wahidin Sudirohusodo Jl. Perintis Kemerdekaan Km 10. Makassar Telp : 0411–582678/586010
  4. Bagian Patologi Klinik FK.UNHAS/RS. Dr. Wahidin Sudirohusodo Makassar/Unit Pelayanan Laboratorium RS Dr. Wahidin Sudirohusodo Jl. Perintis Kemerdekaan Km 10. Makassar Telp : 0411–582678/586010

Abstract :

The reference values of laboratory tests are affected by factors such as instruments and methods of tests, which are always beingdeveloped. For these reasons, each laboratory is recommended to determine their own reference values. To determine the reference valuesof complete blood count in healthy adult people, and compare them to the reference values which is taken from the references. A crosssectional study was conducted on 200 healthy adult people, aged 18-60 years, selected during blood donation. The eight haematologicalparameters were estimated using Sysmex Xt-1800i at Dr.Wahidin Sudirohusodo Hospital. The data were analyzed statistically by SPSS11.5 programs. The reference values of leukocyte, erythrocyte, haemoglobin, hematocrit, MCV, MCH, MCHC and platelet were: 4400 to10000 /µL; %:4.2–6.2 × 106/µL; &:3.8–5.5 × 106/µL; %:12.5–17.3 g/dL; &:11.8–15.4 g/dL; %:38.1–50.4 %; &:31.1–49.7 %; 80,1to 94,3 fL, 25,9–31,9 pg, 31,4–35,2 g/dL, and %:171.2–405.1 × 103/µL; &:191.8–441.5 × 103/µL, respectively. Significant differenceswere observed in the MCH and platelet values (p< 0,005). The values found in this study were similar to the reference value commonlyused in our laboratory, except for the MCH value which was lower and the platelet value which was higher..

Keyword :

Reference value, haematology, healthy adult people, Sysmex Xt-1800i,


References :

  1. Wirawan, (2002). Pemantapan Kualitas Uji Hematologik. Edisi I. Jakarta : Balai Penerbit Fakultas Kedokteran Indonesia
  2. Kresno, (1996). Nilai rujukan. Laporan Kegiatan Perhimpunan Dokter Spesialis Patologi Klinik Indonesia (PDS Patklin), Jakarta PP PDS Patklin, 30 Juni.. - : -
  3. Kresno, (1996). Nilai rujukan. Laporan Kegiatan Perhimpunan Dokter Spesialis Patologi Klinik Indonesia (PDS Patklin), Jakarta PP PDS Patklin, 30 Juni.. - : -
  4. Perkins, (1999). Examination Of The Blood and Bone Marrow, In Wintrobe’s Clinical Hematology. 10th ed. . Baltimore, USA : -
  5. Dacie, (1996). Basic Haematological techniques, In Practical
    Haematology. 8th ed. . Edinburgh : Churchill Livingstone
  6. Corbett, (2004). Hematology Test, In Laboratory Test and Diagnostic
    Procedures with Nursing Diagnosis, 6th Ed. . New Jersey, USA : -
  7. Hardjoeno, (2003). Interpretasi Hasil tes Laboratorium Hematologi.
    Dalam Interpretasi Hasil Tes Laboratorium Diagnostik,
    Lembaga Penerbitan UNHAS. - : -
  8. Kaya, (2000). Hematological Values of Healthy Adult Population Living at Moderate Altitude (1869 m, Erzurum, Turkey). Turky J Haematol. - : -
  9. Kyky, (2000). Hematological Values of Healthy Adult Population Living at Moderate Altitude (1869 m, Erzurum, Turkey). Turky J Haematol. - : -
  10. Akarsu, (2000). Hematological Values of Healthy Adult Population Living at Moderate Altitude (1869 m, Erzurum, Turkey). Turky J Haematol. - : -
  11. Mochsen, (2001). Normal Reference Values For Hematological Parameters, Red Cell Indices, HB A2 and HB F From Early Childhood through Adolescence In Saudis, Annals of Saudi Medicine. - : -
  12. El Hazmi, (2001). Normal Reference Values For Hematological Parameters, Red Cell Indices, HB A2 and HB F From Early Childhood through Adolescence In Saudis, Annals of Saudi Medicine. - : -
  13. Warsi, (2001). Normal Reference Values For Hematological Parameters, Red Cell Indices, HB A2 and HB F From Early Childhood through Adolescence In Saudis, Annals of Saudi Medicine. - : -


   


Archive Article

Cover Media Content

Volume : 12 / No. : 3 / Pub. : 2006-07
  1. Sepsis diagnosis by procalcitonin
  2. The haematology reference value of healthy adult people based on sysmex xt-1800i
  3. Bacteria pattern and antibiotic susceptibility test of pregnant women with asymptomatic bacteriuria)
  4. Bacterial pattern and it’s sensitivity in patients suffering from urinary tract infection
  5. Diagnostic test of plasmodium malaria by immunochromatographic method compared to microscopic examination
  6. Troponin t value/ctnt of patients with acute coronary syndrome)
  7. Plasma cell leukemia
  8. The implementation of concept mapping for quality management in a clinical laboratory
  9. The analysis of urethral stone profile at the clinical pathology laboratory