Indonesian Journal of Clinical Pathology and Medical Laboratory
ISSN 0854-4263
Vol. 12 / No. 3 / Published : 2006-07
Related with : Scholar Yahoo! Bing
Original Article :
The haematology reference value of healthy adult people based on sysmex xt-1800i
Author :
- T.Esa*1
- S.Aprianti*2
- M.Arif*3
- Hardjoeno*4
- Bagian Patologi Klinik FK.UNHAS/RS. Dr. Wahidin Sudirohusodo Makassar/ Unit Pelayanan Laboratorium RS Dr. Wahidin Sudirohusodo Jl. Perintis Kemerdekaan Km 10. Makassar Telp : 0411–582678/586010
- Bagian Patologi Klinik FK.UNHAS/RS. Dr. Wahidin Sudirohusodo Makassar/Unit Pelayanan Laboratorium RS Dr. Wahidin Sudirohusodo Jl. Perintis
Kemerdekaan Km 10. Makassar Telp : 0411–582678/586010 - Bagian Patologi Klinik FK.UNHAS/RS. Dr. Wahidin Sudirohusodo Makassar/Unit Pelayanan Laboratorium RS Dr. Wahidin Sudirohusodo Jl. Perintis Kemerdekaan Km 10. Makassar Telp : 0411–582678/586010
- Bagian Patologi Klinik FK.UNHAS/RS. Dr. Wahidin Sudirohusodo Makassar/Unit Pelayanan Laboratorium RS Dr. Wahidin Sudirohusodo Jl. Perintis Kemerdekaan Km 10. Makassar Telp : 0411–582678/586010
Abstract :
The reference values of laboratory tests are affected by factors such as instruments and methods of tests, which are always beingdeveloped. For these reasons, each laboratory is recommended to determine their own reference values. To determine the reference valuesof complete blood count in healthy adult people, and compare them to the reference values which is taken from the references. A crosssectional study was conducted on 200 healthy adult people, aged 18-60 years, selected during blood donation. The eight haematologicalparameters were estimated using Sysmex Xt-1800i at Dr.Wahidin Sudirohusodo Hospital. The data were analyzed statistically by SPSS11.5 programs. The reference values of leukocyte, erythrocyte, haemoglobin, hematocrit, MCV, MCH, MCHC and platelet were: 4400 to10000 /µL; %:4.2–6.2 × 106/µL; &:3.8–5.5 × 106/µL; %:12.5–17.3 g/dL; &:11.8–15.4 g/dL; %:38.1–50.4 %; &:31.1–49.7 %; 80,1to 94,3 fL, 25,9–31,9 pg, 31,4–35,2 g/dL, and %:171.2–405.1 × 103/µL; &:191.8–441.5 × 103/µL, respectively. Significant differenceswere observed in the MCH and platelet values (p< 0,005). The values found in this study were similar to the reference value commonlyused in our laboratory, except for the MCH value which was lower and the platelet value which was higher..
Keyword :
Reference value, haematology, healthy adult people, Sysmex Xt-1800i,
References :
Wirawan,(2002) Pemantapan Kualitas Uji Hematologik. Edisi I Jakarta : Balai Penerbit Fakultas Kedokteran Indonesia
Kresno,(1996) Nilai rujukan. Laporan Kegiatan Perhimpunan Dokter Spesialis Patologi Klinik Indonesia (PDS Patklin), Jakarta PP PDS Patklin, 30 Juni. - : -
Kresno,(1996) Nilai rujukan. Laporan Kegiatan Perhimpunan Dokter Spesialis Patologi Klinik Indonesia (PDS Patklin), Jakarta PP PDS Patklin, 30 Juni. - : -
Perkins,(1999) Examination Of The Blood and Bone Marrow, In Wintrobe’s Clinical Hematology. 10th ed. Baltimore, USA : -
Dacie,(1996) Basic Haematological techniques, In Practical
Haematology. 8th ed. Edinburgh : Churchill Livingstone
Corbett,(2004) Hematology Test, In Laboratory Test and Diagnostic
Procedures with Nursing Diagnosis, 6th Ed. New Jersey, USA : -
Hardjoeno,(2003) Interpretasi Hasil tes Laboratorium Hematologi.
Dalam Interpretasi Hasil Tes Laboratorium Diagnostik,
Lembaga Penerbitan UNHAS - : -
Archive Article
| Cover Media | Content |
|---|---|
![]() Volume : 12 / No. : 3 / Pub. : 2006-07 |
|