Various polymerization temperature on dimensional accuracy of orthodontic acrylic base plate

Author :

  1. Elly Rusdiana*1
  1. Department of Orthodontic, Faculty of Dentistry Airlangga University,
    Surabaya - Indonesia

Abstract :

Cold curing acrylic is more porous, having more residual monomer and dimensional change. Physical property of cold curing acrylic shows to have very small dimensional change resulted from imperfect polymerization process and if dimensional change occurs, it would cause improper use of orthodontic appliance. Orthodontic acrylic base plate which is made of cold curing acrylic, in order to achieve good result, it is suggested to use hydro flask or polyclav with water temperature 450 C-500C and polyclav and pressure in 2-3 atm during polymerization process. Even though cold curing acrylic could polymerization at room temperature, the purpose to use hydro flask or polyclav is to reduce residual monomer and porosity. The purpose of the present study is to know the difference in dimensional accuracy of orthodontic acrylic at various polymerization temperature. The samples of the study were 18 acrylic base plate sized 65 x 10 x 25 mm classified into 3 control groups with polymerization temperature at 300 C, 400 C and 500 C. Measurement was done using caliper in order to know dimensional accuracy of orthodontic acrylic. The measurement result was tabulated and One-Way ANOVA test one was done with significant level 95%, the probability result 0,0055 was found which means there was significant difference among each control group. LSD test showed that group I polymerization at 300C, group II polymerization at 400 C, and group III polymerization at 500C there was significant difference. The conclusion of this study is : dimensional difference of orthodontic acrylic base plate on polymerization at group I at 300 C, group II at 400 C, and group III at 500 C water temperature and could achieve better dimensional accuracy comparing with polymerization at 500 C.

Keyword :

cold curing acrylic, dimension, polymerization ,


References :





Archive Article

Cover Media Content

Volume : 40 / No. : 4 / Pub. : 2007-12
  1. The Management Of Oral Erythema Multiforme In Juvenile Patient
  2. The Citotoxicity Of Calcium Hydroxide Intracanal Dressing By Mtt Assay
  3. The Correction Of Occlusal Vertical Dimension On Tooth Wear
  4. The Effect Of Gender Differences On Dentist's Performance (a Study In Health Centers In East Java)
  5. Various Polymerization Temperature On Dimensional Accuracy Of Orthodontic Acrylic Base Plate
  6. The Ability Of 5% Tamarindus Indica Extract As Cleaner Of The Root Canal Wall Smear Layer
  7. A New Concept In Orthodontics: Faster And Healthier Tooth Movement By Regularly Consuming Xyilitol Chewing Gum
  8. The Application Of Methacrylate Resin And The Derivation As Restorative Material Of Damaged Tooth Tissue
  9. The Clinical Potential And Limits Of The All-ceramic Fixed Partial Denture Restorations
  10. Closed Mouth Method With Dynamic And Muco Compressive Impression On Upper And Lower Jaw Ridges For Aid Full Denture Retention