Abstract :

This study was done to make the system of electro-mechanical arm ergometer cycle that will be used as a post-stroke patient physiotherapy. The management system was expected to set the rotary frequency according to the therapeutic needs. To set the frequency of the rotation, the PID control with rotation sensor was used as feedback. The rotating sensor which used consisted of the opto-coupler and a rotary encoder. Based on the research that has been done obtained constants ofKp = 0055, Ki and Kd = 2545 = 0.00005. Constants were selected because they were the most optimum constant trial and error method. The system is made to have a greater percentage of error of 5%. In this study, the response time values obtained for each additional mass of the load at each frequency setting result is increased.

Keyword :

physioteraphy, hand muscle, rotary frequency, PID, PWM,


References :

  1. Andrianto, H., (2008). Pemrograman Mikrokontroler AVR ATMega 16 Menggunakan Bahasa C. - : Yogyakarta: Andi Publisher
  2. Dalimin, (2006). Rancang Bangun Dan Proses Pembuatan Prosthesis PTB Supra Condylar Kanan Pada Amputasi Bawah Lutut. - : Poltekkes Surakarta Progam Studi Orthotik Prosthetik, Surakarta
  3. Diserens, K., Perret, N., Chatelain, S., Bashir, S., Ruegg, D., Vuandens, P., Vingerhoets, F., (2007). The Effect of Repetitive Arm Cycling on Post Stroke Spasticity and Motor Control Repetitive Arm Cycling and Spasticity. - : Switzerland: Journal of the Neurological Sciences


   


Archive Article

Cover Media Content

Volume : 4 / No. : 3 / Pub. : 2016-12
  1. Pelapisan hidroksiapatit dari tulang sotong (sepia sp.) pada ss316l untuk aplikasi implan tulang prostetik
  2. Analisis termal suspensi injectable bone substitute (ibs) berbasis komposit hidroksiapatit dan gelatin
  3. Aplikasi probe serat optik multimode berbentuk u untuk mendeteksi kelembapan relatif udara
  4. Rancang bangun sistem elektro-mekanik arm cycle ergometer rehabilitasi medis pasca stroke
  5. Rancang bangun sensor kadar urea memanfaatkan rugi daya antar ujung dua serat optik
  6. Pengaruh variasi waktu milling terhadap karakteristik semen gigi glass ionomer cement (gic)
  7. Optimalisasi variasi komposisi penambahan zno nanopartikel terhadap karakteristik hidroksiapatit berpori sebagai bone filler
  8. Aplikasi fiber coupler sebagai sensor konsentrasi urea
  9. Pengaruh penambahan zat aditif mgo nanopartikel terhadap karakteristik hidroksiapatit berpori sebagai bone filler