Optimasi model elektrode pada sistem pengukuran potensial titik akupunktur secara non- invasive untuk diagnosis fungsional organ

Author :

  1. Yulanda Dwi Fajarwati*1
  2. Welina Ratnayanti Kawitana*2
  3. Tri Anggono Prijo*3
  1. Mahasiswa Fakultas Sains dan Teknologi
  2. Dosen Fakultas Sains dan Teknologi
  3. Dosen Fakultas Sains dan Teknologi

Abstract :

This study aim to make an electrode as a substitute for standard ECG electrodes. The electrodes were made from pieces of aluminum and innovation did in 2 ways, the diameter and the addition of a magnetic field. Data retrieval is done by recording the acupuncture points PC 6 (Neiguan) associated with the heart. Recording done using software and data generated IWORX/214 data such as voltage function of time. Potential profile patterned recording ECG results because it is the acupuncture point of pericardial heart. ECG pattern was observed amplitude of frequency appears. The success rate of the electrode measured ability raises the maximum amplitude in the frequency appears. The results of the analysis stated there are several dominant frequencies that arise from the potential profile recording acupuncture points, the frequency of 0-2 Hz and 50 Hz. The best electrode for detecting the frequency of 0-2 Hz is the electrode with a diameter of 2.8 cm with a value of amplitude A = (1 ± 0.16). While the electrode is best to minimize the noise frequency is 50 Hz electrode with a diameter of 2.8 cm and with the addition of 1 to the value of the magnetic plate amplitude A = (0.03 ± 0.01). Based on the results obtained, the electrodes have been made in this study can replace the standard electrode because it can detect the electrical potential profile in acupuncture point PC 6 quite well when compared to the standard ECG electrodes manufactured

Keyword :

Electrode, Voltage, Frequency, Amplitude, ECG,


References :

Aminatun, Izak,(2002) Bahan Ajar Fisika Zat Padat - : UNAIR

Aston, R,(1990) Principles of Biomedical Instrumentation and Measurement - : Merrill Publishing Company

Boas and Mary, L.,(1983) Mathematical Methods in the Physical Sciences Second Edition 2nd Edition : Johns Wiley & Sons, Inc.

Erawati, P., Astuti, S. D., dan Prijo, T. A. dkk,(2003) Analisis Profil Potensial Untuk Kelainan Fungsional Organ - : Lembaga Penelitian UNAIR

Gabriel, J. F.,(1996) Fisika Kedokteran - : EGC





Archive Article

Cover Media Content

Volume : 1 / No. : 3 / Pub. : 2013-08
  1. Sintesis Membran Penyaring Logam Berat Timbal (pb) Di Udara Berbasis Selulosa Asetat Dari Eceng Gondok (eichhornia Crassipes)
  2. Sensor Ketinggian Permukaan Oli Berbasis Sensor Pergeseran Fiber Coupler
  3. Potensi Induksi Medan Magnet Eksternal Untuk Efektivitas Fotoinaktivasi Bakteri Patogen
  4. Sintesis Dan Karakterisasi Sifat Mekanik Mortar Berbasis Material Komposit Silika Amorf Dengan Variasi Penambahan Sekam Tebu
  5. Analisis Perubahan Profil Potensial Titik Akupunktur Penderita Diabetes Melitus Terhadap Paparan Laserpunktur
  6. Optimasi Model Elektrode Pada Sistem Pengukuran Potensial Titik Akupunktur Secara Non- Invasive Untuk Diagnosis Fungsional Organ
  7. Implementasi Learning Vector Quantization (lvq) Sebagai Alat Bantu Identifikasi Kelainan Jantung Melalui Citra Elektrokardiogram
  8. Rancang Bangun Syringe Pump Berbasis Mikrokontroler Atmega8535 Dilengkapi Detektor Oklusi
  9. Rancang Bangun Sistem Optimasi Infus Drop Rate
  10. Sintesis Bahan Cetak Gigi Natrium Alginat Dari Alga Coklat Sargassum Sp. Yang Berpotensi Untuk Aplikasi Klinis